    Hyperbaric oxygen therapy (HBOT) is one of the fastest-growing service lines in U.S. hospitals, wound-care centers, and specialty clinics. But installing a hyperbaric chamber is not a simple equipment delivery, it's a coordinated build-out governed by NFPA 99 Chapter 14 (Hyperbaric Facilities), NFPA 99 Chapter 5 (Medical Gas and Vacuum Systems), local AHJ amendments, and the chamber OEM's own requirements.

    This guide walks through everything a facility manager, biomed director, or project owner should know before signing the PO.

    Monoplace vs. Multiplace: Pick the Right Chamber First

    Monoplace chambers treat a single patient in a 100% oxygen environment, pressurized typically to 2.0–3.0 ATA. They are the most common chamber in U.S. wound-care centers because they have a smaller footprint, lower oxygen draw, and a simpler regulatory profile.

    Multiplace chambers are pressurized vessels (usually with air) where multiple patients breathe oxygen through BIBS masks or hoods. They allow staff inside the chamber, support critical-care patients, and are required for certain emergency indications like decompression sickness or gas embolism.

    NFPA 99 Chapter 14: The Code You Cannot Skip

    NFPA 99 Chapter 14 governs everything from chamber location and ventilation to oxygen storage and electrical bonding. Key requirements include:

    • Dedicated mechanical ventilation with proper air-change rates
    • Oxygen storage sized for peak demand plus reserve
    • Vent stacks that exhaust safely outside the building
    • Fire-suppression coordination with the chamber and surrounding space
    • Supervised master and area alarms tied to the medical-gas system
    • Electrical bonding and isolation per NFPA 70

    Oxygen Piping: Where Projects Most Often Go Wrong

    Hyperbaric oxygen demand is dramatically higher than a standard patient outlet. A monoplace chamber can pull 200–300 SLPM during a treatment. Multiplace systems can draw thousands of SLPM. The piping has to be sized, oxygen-cleaned, and brazed by qualified [ASSE 6010](/medical-gas-installation) installers, and then verified by an [ASSE 6030](/medical-gas-verification) verifier before patient use.

    Alarms: The Other System That Has to Be Right

    Every HBO suite must be tied into the facility's master alarm and area alarm system. That means supervised low-voltage cabling, properly labeled panels, and end-to-end commissioning. If your alarm wiring is shaky, the chamber doesn't go live. See our medical gas low-voltage wiring page for how we handle alarm scope.

    Commissioning Checklist

    1. Site survey and oxygen storage plan
    2. Rigging, leveling, and anchoring the chamber
    3. Oxygen-cleaned, brazed piping per NFPA 99
    4. Vent stack and pressure relief tie-in
    5. Master and area alarm integration
    6. Electrical bonding and emergency power
    7. Leak-down and pressurization testing
    8. Oxygen cleanliness verification
    9. Operator training and PM schedule hand-off
    10. Final commissioning report for the AHJ

    Should You Buy New or Refurbished?

    A new monoplace chamber from a major OEM (Sechrist, Perry Baromedical, ETC) typically lists between $130,000 and $200,000 before installation. A certified-refurbished monoplace runs roughly 40–60% of new. Refurbished chambers are an excellent option when sourced from a vendor that pressure-tests, recertifies, and warranties the unit.

    Who Should Own the Whole Project?

    Most HBO build-outs go sideways when responsibility is fragmented across the chamber OEM, a mechanical contractor, an electrician, and a separate verifier. The fix is straightforward: have one accountable team scope the chamber, the piping, the alarms, and the verification together. That's how MTS structures every hyperbaric project.

    Planning a hyperbaric build-out? Request a scoped quote or call (754) 315-1078 and we'll walk through the project with you.

    Frequently Asked Questions

    Yes. We install monoplace and multiplace chambers and coordinate rigging, oxygen piping, alarms, electrical, and OEM commissioning so the chamber is ready for patient use.

    NFPA 99 Chapter 14 (Hyperbaric Facilities) plus NFPA 99 Chapter 5 for medical gas piping, and applicable local AHJ amendments.

    Yes. Our ASSE 6030 verifiers test the oxygen supply piping, master and area alarms, ventilation, and chamber interlocks and deliver a digital report for your AHJ.

    Yes. We source certified-refurbished monoplace chambers (Sechrist, Perry Baromedical, ETC) and also offer new OEM chambers with full warranty.

    A monoplace install usually takes 3-5 working days once the room is ready. Multiplace and full HBO suites take 2-6 weeks depending on storage, ventilation, and electrical scope.

    This article is provided for educational purposes and reflects industry standards as of publication. Always verify against current NFPA 99, CGA, and AHJ requirements. Medical Testing Solutions is ASSE-certified and ready to help — contact us for facility-specific guidance.

    Request a quote for your facility

    Talk with Medical Testing Solutions about your next inspection, repair or equipment request.

    Get a quote in 1 business day

    I agree to receive text messages from Medical Testing Solutions, L.L.C. at the phone number provided, including informational and marketing messages. Consent is not a condition of purchase. Message frequency varies. Message & data rates may apply. Reply STOP to opt out or HELP for help. See our Privacy Policy and Messaging Terms.