The medical gas industry's most common question — "what part replaces this old outlet?" — answered. Cross-reference legacy Chemetron, Ohio Diamond, Puritan-Bennett, Oxequip, NCG, and Schrader outlets to current Amico, Ohio Medical, Allied, Tri-Tech, and Beacon Medaes assemblies with NFPA 99 compliance notes and one-click quote requests.
Modern brand:56 mappings
| Gas | Legacy Outlet | Modern Replacement | Action | Quote |
|---|---|---|---|---|
Oxygen | Chemetron Quick Connect | Amico — OL-OXY-D-CHEM Amico Oxygen Outlet, Chemetron-compatible back-body | Front-body swap (back-body retained) | |
Oxygen | Chemetron Quick Connect | Ohio Medical — 0220-0001-800 Ohio Medical OneStep Oxygen, Chemetron retrofit | Front-body swap (back-body retained) | |
Oxygen | Chemetron Quick Connect | Tri-Tech Medical — TT-O2-CHEM Tri-Tech Oxygen front-body, Chemetron pattern | Front-body swap (back-body retained) | |
Medical Air | Chemetron Quick Connect | Amico — OL-AIR-D-CHEM Amico Medical Air Outlet, Chemetron-compatible | Front-body swap (back-body retained) | |
Medical Air | Chemetron Quick Connect | Ohio Medical — 0220-0002-800 Ohio Medical OneStep Air, Chemetron retrofit | Front-body swap (back-body retained) | |
Vacuum | Chemetron Quick Connect | Amico — OL-VAC-D-CHEM Amico Vacuum Outlet, Chemetron-compatible | Front-body swap (back-body retained) | |
Vacuum | Chemetron Quick Connect | Ohio Medical — 0220-0003-800 Ohio Medical OneStep Vacuum, Chemetron retrofit | Front-body swap (back-body retained) | |
Nitrous Oxide | Chemetron Quick Connect | Amico — OL-N2O-D-CHEM Amico Nitrous Outlet, Chemetron-compatible | Front-body swap (back-body retained) | |
Nitrogen | Chemetron Quick Connect | Amico — OL-N2-D-CHEM Amico Nitrogen Outlet, Chemetron-compatible | Front-body swap (back-body retained) | |
WAGD | Chemetron Quick Connect | Amico — OL-WAG-D-CHEM Amico WAGD Outlet, Chemetron-compatible | Front-body swap (back-body retained) | |
Oxygen | Ohio Diamond Diamond Series | Amico — OL-OXY-D-OHD Amico Oxygen Outlet, Ohio Diamond pattern | Front-body swap (back-body retained) | |
Oxygen | Ohio Diamond Diamond Series | Ohio Medical — 0220-0001-810 Ohio Medical OneStep, Diamond-to-OneStep retrofit | Front-body swap (back-body retained) | |
Medical Air | Ohio Diamond Diamond Series | Amico — OL-AIR-D-OHD Amico Medical Air Outlet, Ohio Diamond pattern | Front-body swap (back-body retained) | |
Vacuum | Ohio Diamond Diamond Series | Amico — OL-VAC-D-OHD Amico Vacuum Outlet, Ohio Diamond pattern | Front-body swap (back-body retained) | |
Nitrous Oxide | Ohio Diamond Diamond Series | Amico — OL-N2O-D-OHD Amico Nitrous Outlet, Ohio Diamond pattern | Front-body swap (back-body retained) | |
Nitrogen | Ohio Diamond Diamond Series | Amico — OL-N2-D-OHD Amico Nitrogen Outlet, Ohio Diamond pattern | Front-body swap (back-body retained) | |
Oxygen | Puritan-Bennett Puritan | Amico — OL-OXY-D-PB Amico Oxygen Outlet, Puritan-Bennett pattern | Front-body swap (back-body retained) | |
Oxygen | Puritan-Bennett Puritan | Ohio Medical — 0220-0001-820 Ohio Medical OneStep, Puritan retrofit | Front-body swap (back-body retained) | |
Oxygen | Puritan-Bennett Puritan | Allied Healthcare — L1OUTPB Allied Diss-Aware Oxygen, Puritan back-body adapter | Adapter / quick-connect change | |
Medical Air | Puritan-Bennett Puritan | Amico — OL-AIR-D-PB Amico Air Outlet, Puritan-Bennett pattern | Front-body swap (back-body retained) | |
Vacuum | Puritan-Bennett Puritan | Amico — OL-VAC-D-PB Amico Vacuum Outlet, Puritan-Bennett pattern | Front-body swap (back-body retained) | |
Nitrous Oxide | Puritan-Bennett Puritan | Amico — OL-N2O-D-PB Amico Nitrous Outlet, Puritan-Bennett pattern | Front-body swap (back-body retained) | |
Oxygen | Oxequip Life-Line | Amico — OL-OXY-D-OXQ Amico Oxygen Outlet, Oxequip Life-Line pattern | Front-body swap (back-body retained) | |
Oxygen | Oxequip Life-Line | Tri-Tech Medical — TT-O2-OXQ Tri-Tech Oxygen front-body, Oxequip pattern | Front-body swap (back-body retained) | |
Medical Air | Oxequip Life-Line | Amico — OL-AIR-D-OXQ Amico Medical Air Outlet, Oxequip pattern | Front-body swap (back-body retained) | |
Vacuum | Oxequip Life-Line | Amico — OL-VAC-D-OXQ Amico Vacuum Outlet, Oxequip pattern | Front-body swap (back-body retained) | |
Nitrous Oxide | Oxequip Life-Line | Amico — OL-N2O-D-OXQ Amico Nitrous Outlet, Oxequip pattern | Front-body swap (back-body retained) | |
WAGD | Oxequip Life-Line | Amico — OL-WAG-D-OXQ Amico WAGD Outlet, Oxequip pattern | Front-body swap (back-body retained) | |
Oxygen | NCG / National Cylinder Gas NCG | Amico — OL-OXY-D-NCG Amico Oxygen Outlet, NCG pattern | Front-body swap (back-body retained) | |
Medical Air | NCG / National Cylinder Gas NCG | Amico — OL-AIR-D-NCG Amico Air Outlet, NCG pattern | Front-body swap (back-body retained) | |
Vacuum | NCG / National Cylinder Gas NCG | Amico — OL-VAC-D-NCG Amico Vacuum Outlet, NCG pattern | Front-body swap (back-body retained) | |
Oxygen | Schrader / Hill-Rom Schrader BSI | Amico — OL-OXY-D-SCH Amico Oxygen Outlet, Schrader/BSI pattern | Full outlet assembly replacement | |
Medical Air | Schrader / Hill-Rom Schrader BSI | Amico — OL-AIR-D-SCH Amico Air Outlet, Schrader/BSI pattern | Full outlet assembly replacement | |
Vacuum | Schrader / Hill-Rom Schrader BSI | Amico — OL-VAC-D-SCH Amico Vacuum Outlet, Schrader/BSI pattern | Full outlet assembly replacement | |
Oxygen | Ohio Medical (Legacy) Pre-OneStep | Ohio Medical — 0220-0001-800 Ohio Medical OneStep Oxygen | Rebuild kit (in-place) Rebuild kit available | |
Medical Air | Ohio Medical (Legacy) Pre-OneStep | Ohio Medical — 0220-0002-800 Ohio Medical OneStep Air | Rebuild kit (in-place) Rebuild kit available | |
Vacuum | Ohio Medical (Legacy) Pre-OneStep | Ohio Medical — 0220-0003-800 Ohio Medical OneStep Vacuum | Rebuild kit (in-place) Rebuild kit available | |
Nitrous Oxide | Ohio Medical (Legacy) Pre-OneStep | Ohio Medical — 0220-0004-800 Ohio Medical OneStep Nitrous | Rebuild kit (in-place) Rebuild kit available | |
Oxygen | Allied (Legacy) Allied Series | Allied Healthcare — L1OUT-O2 Allied Diss-Aware Oxygen Outlet (current production) | Rebuild kit (in-place) Rebuild kit available | |
Medical Air | Allied (Legacy) Allied Series | Allied Healthcare — L1OUT-AIR Allied Diss-Aware Air Outlet | Rebuild kit (in-place) Rebuild kit available | |
Vacuum | Allied (Legacy) Allied Series | Allied Healthcare — L1OUT-VAC Allied Diss-Aware Vacuum Outlet | Rebuild kit (in-place) Rebuild kit available | |
Oxygen | Amico (Legacy) Amico Classic | Amico — OL-OXY-D-AM Amico Alert-2 Oxygen Outlet (current) | Front-body swap (back-body retained) | |
Medical Air | Amico (Legacy) Amico Classic | Amico — OL-AIR-D-AM Amico Alert-2 Air Outlet (current) | Front-body swap (back-body retained) | |
Vacuum | Amico (Legacy) Amico Classic | Amico — OL-VAC-D-AM Amico Alert-2 Vacuum Outlet (current) | Front-body swap (back-body retained) | |
Oxygen | Tri-Tech (Legacy) Tri-Tech 100 Series | Tri-Tech Medical — TT-100-O2 Tri-Tech 100-Series Oxygen Rebuild Kit | Rebuild kit (in-place) Rebuild kit available | |
Medical Air | Tri-Tech (Legacy) Tri-Tech 100 Series | Tri-Tech Medical — TT-100-AIR Tri-Tech 100-Series Air Rebuild Kit | Rebuild kit (in-place) Rebuild kit available | |
Vacuum | Tri-Tech (Legacy) Tri-Tech 100 Series | Tri-Tech Medical — TT-100-VAC Tri-Tech 100-Series Vacuum Rebuild Kit | Rebuild kit (in-place) Rebuild kit available | |
Oxygen | Schrader / Hill-Rom Beacon Medaes Legacy | Beacon Medaes — BM-OXY-RTRO Beacon Medaes Oxygen Retrofit Outlet | Front-body swap (back-body retained) | |
Medical Air | Schrader / Hill-Rom Beacon Medaes Legacy | Beacon Medaes — BM-AIR-RTRO Beacon Medaes Medical Air Retrofit Outlet | Front-body swap (back-body retained) | |
Vacuum | Schrader / Hill-Rom Beacon Medaes Legacy | Beacon Medaes — BM-VAC-RTRO Beacon Medaes Vacuum Retrofit Outlet | Front-body swap (back-body retained) | |
Vacuum | Ohio Medical (Legacy) Continuous Vacuum Regulator | Ohio Medical — 1535-3001-800 Ohio Medical Push-to-Set Continuous Vacuum Regulator | Manifold or regulator replacement Rebuild kit available | |
Vacuum | Allied (Legacy) Intermittent Suction Regulator | Allied Healthcare — L378-ISR Allied Intermittent Suction Regulator | Manifold or regulator replacement Rebuild kit available | |
Medical Air | Ohio Medical (Legacy) Air/O2 Blender | Precision Medical — PM5200 Precision Medical Air/Oxygen Blender | Full outlet assembly replacement | |
Medical Air | Powerex (Legacy) SES Series | Powerex — SES-RBLD-KIT Powerex SES Compressor Rebuild Kit | Rebuild kit (in-place) Rebuild kit available | |
Instrument Air | Chemetron Surgical Inlet | Amico — OL-IA-D-CHEM Amico Instrument Air Outlet, Chemetron pattern | Front-body swap (back-body retained) | |
Carbon Dioxide | Chemetron Quick Connect | Amico — OL-CO2-D-CHEM Amico CO₂ Outlet, Chemetron pattern | Front-body swap (back-body retained) |
Not sure which outlet you have?
Email a clear photo of the outlet front-body to sales@medicaltestingsolutions.com with your facility name and gas service. An ASSE 6030 verifier will reply within 1 business day with the correct retrofit path and pricing.
Manufacturer Cross-Ref Sources
Amico Retrofit Catalog
Ohio Medical OneStep Cross-Reference
Allied Healthcare Diss-Aware Series
Tri-Tech 100-Series Service Bulletins
Beacon Medaes Retrofit Program
Powerex Compressor Field Rebuild Kits
Industry Service We Provide
Need help fast?
An ASSE 6030 verifier can confirm your retrofit path in under 1 business day.
(754) 315-1078Email Sales