USP 797 and USP 800 are United States Pharmacopeia chapters that establish enforceable standards for sterile compounding and hazardous drug handling in healthcare facilities. Compliance with these standards is not optional, they are adopted by most state boards of pharmacy, CMS, and accreditation bodies including The Joint Commission. Medical Testing Solutions provides comprehensive USP 797/800 compliance services including environmental monitoring, air quality testing, and certification.
USP 797 & 800 Compliance: Sterile Compounding & Hazardous Drug Safety
What Is USP 797?
USP General Chapter 797 sets minimum standards for sterile compounding to protect patients from contamination, infection, and dosing errors. It applies to all facilities that prepare compounded sterile preparations (CSPs), including:
- Hospital pharmacies
- Outpatient infusion centers
- Nuclear pharmacies
- Ophthalmology compounding facilities
- Veterinary compounding pharmacies
Key USP 797 Requirements
- Classified cleanroom environments, ISO 5, ISO 7, and ISO 8 air quality classifications
- Personnel training and competency, garbing, hand hygiene, and aseptic technique
- Environmental monitoring, viable and non-viable particle sampling
- Beyond-Use Dating (BUD), based on sterility testing and risk categories
- Cleaning and disinfection protocols with documented frequencies
- Quality assurance programs including media fill testing
What Is USP 800?
USP General Chapter 800 establishes standards for the safe handling of hazardous drugs (HDs) to protect healthcare workers, patients, and the environment. It covers the full lifecycle of hazardous drugs:
- Receiving and storage
- Compounding and preparation
- Administration
- Disposal and spill management
- Environmental monitoring and decontamination
Key USP 800 Requirements
- Containment primary engineering controls (C-PECs), biological safety cabinets, CACIs
- Containment secondary engineering controls (C-SECs), negative pressure rooms with dedicated HVAC
- Closed-system transfer devices (CSTDs) for drug administration
- Personal protective equipment (PPE), chemotherapy-rated gloves, gowns, respirators
- Surface wipe sampling to verify decontamination effectiveness
- Medical surveillance programs for exposed workers
Why Environmental Monitoring Matters
Environmental monitoring is the backbone of USP 797/800 compliance. Without regular testing, facilities cannot verify that their cleanrooms and containment areas meet required air quality standards.
Air Quality Testing
- Non-viable particle counts, laser particle counters verify ISO classification
- Viable air sampling, active and passive sampling to detect microbial contamination
- Airflow visualization (smoke studies), confirm unidirectional airflow patterns
- HEPA filter integrity testing, DOP/PAO challenge testing per IEST-RP-CC034
Surface Monitoring
- Contact plates and swabs for viable surface sampling
- Hazardous drug surface wipe sampling to verify decontamination (USP 800)
- Formaldehyde, xylene, and chemical vapor monitoring for hazardous chemical exposure
MTS USP 797/800 Compliance Services
Medical Testing Solutions offers full-service USP compliance programs that include:
- Initial facility assessment, gap analysis against current USP requirements
- Cleanroom certification, ISO classification testing per ISO 14644
- HEPA filter integrity testing, annual DOP/PAO testing
- Viable and non-viable environmental monitoring programs
- Hazardous drug surface wipe sampling, quantitative analysis
- WAG and chemical vapor monitoring, nitrous oxide, formaldehyde, glutaraldehyde
- Comprehensive reporting for state board, CMS, and accreditation surveys
- Staff training on proper monitoring techniques and documentation
Common Compliance Gaps We Find
After performing hundreds of USP assessments nationwide, these are the most frequent deficiencies we identify:
- Inadequate pressure differentials between cleanroom zones
- Missing or outdated environmental monitoring programs
- Improper garbing procedures and insufficient competency documentation
- No hazardous drug surface wipe testing (USP 800 requirement)
- HEPA filters not tested annually or after any HVAC maintenance
- Incomplete cleaning logs and missing disinfectant contact time documentation
Frequently Asked Questions
Request a quote for your facility