Compressed air isn't just "air." In a medical, pharmaceutical, or food processing environment, it's a critical utility that directly impacts patient safety, product integrity, and regulatory compliance. But how do you define "clean"? The answer lies in ISO 8573, the international standard for compressed air quality. Navigating its tables and classifications can feel overwhelming, but it doesn't have to be. This definitive guide translates the technical jargon of ISO 8573-1:2010 into plain English. You will learn what the purity classes for particles, water, and oil mean, how they relate to critical audits like SQF and BRC, and how to determine the precise air quality your facility needs to maintain safety and compliance.
ISO 8573 Compressed Air Testing: A Plain-English Guide

What is ISO 8573-1:2010?
ISO 8573 is a multi-part international standard that specifies the quality of compressed air. Part 1, designated as ISO 8573-1:2010, is the cornerstone. It provides a classification system for the main contaminants found in a compressed air system: solid particles, water, and oil.
Think of it as a universal language for air purity. It allows a facility in Florida to use the same precise terminology as a facility in Germany. This standard is crucial because it's the benchmark referenced by numerous other regulatory and quality systems, including those in the medical, pharmaceutical, and food and beverage industries. The other parts of the standard (ISO 8573-2 through ISO 8573-9) specify the testing methods required to measure these contaminants.
Deconstructing the ISO 8573 Purity Classes: The "Big Three" Contaminants
ISO 8573-1 classifies air purity using a three-part code, often written as [P:W:O]. Each letter corresponds to one of the "big three" contaminants.
- [P] stands for Particles: This refers to solid particulates like dust, rust, pipe scale, and microorganisms.
- [W] stands for Water: This includes water vapor, which is measured by its pressure dew point (PDP), and liquid water.
- [O] stands for Oil: This class covers oil in all its forms, liquid, aerosol, and vapor.
When you see a classification like "ISO 8573-1:2010 Class 1:2:1," it means the air must meet Class 1 for Particles, Class 2 for Water, and Class 1 for Oil.
Solid Particles (P)
The particle classification (Classes 0-7) specifies the maximum number of particles allowed per cubic meter of air, categorized by their size (in microns, or μm). The lower the class number, the fewer particles are permitted. This is critical for preventing contamination of sensitive products or obstruction of medical devices.
Water (W)
The water classification (Classes 0-9X) is primarily determined by the pressure dew point (PDP). PDP is the temperature at which water vapor in the compressed air will condense into liquid water at the current pressure. A lower PDP means the air is drier. For instance, Class 2 requires a PDP of -40°F (-40°C), which is a common requirement for medical air systems to prevent moisture from reaching patients or equipment. Preventing liquid water is essential to inhibit microbial growth and prevent corrosion within your piping network. Regular maintenance of your medical gas system is key to managing moisture levels effectively.
Oil (O)
The oil classification (Classes 0-4) sets the maximum concentration of total oil (aerosol, liquid, and vapor) in milligrams per cubic meter (mg/m³). In medical and food-grade applications, oil is a particularly hazardous contaminant. Even "oil-free" compressors can ingest oil vapors from the ambient air, which are then concentrated in the compression process. This makes robust filtration and regular, accurate testing indispensable.
The ISO 8573-1:2010 Purity Class Table Explained
This table is the heart of the standard. It provides the specific limits for each purity class.
| Purity Class | Solid Particles (by size in μm) | Water (Pressure Dew Point) | Oil (Total: aerosol, liquid, vapor) |
|---|---|---|---|
| 0 | As specified by the equipment user or supplier and more stringent than Class 1. | As specified by the equipment user or supplier and more stringent than Class 1. | As specified by the equipment user or supplier and more stringent than Class 1. |
| 1 | ≤ 20,000 (0.1-0.5μm), ≤ 400 (0.5-1.0μm), ≤ 10 (1.0-5.0μm) | -94°F (-70°C) | ≤ 0.01 mg/m³ |
| 2 | ≤ 400,000 (0.1-0.5μm), ≤ 6,000 (0.5-1.0μm), ≤ 100 (1.0-5.0μm) | -40°F (-40°C) | ≤ 0.1 mg/m³ |
| 3 | Not specified, ≤ 90,000 (0.5-1.0μm), ≤ 1,000 (1.0-5.0μm) | -4°F (-20°C) | ≤ 1 mg/m³ |
| 4 | Not specified, Not specified, ≤ 10,000 (1.0-5.0μm) | +38°F (+3°C) | ≤ 5 mg/m³ |
| 5 | Not specified, Not specified, ≤ 100,000 (1.0-5.0μm) | +45°F (+7°C) | ≤ 25 mg/m³ |
| 6 | Not specified | +50°F (+10°C) | Not specified |
| 7 | Not specified | Class 7 specifies liquid water content, not PDP (C_w ≤ 0.5 g/m³) | Not specified |
| 8 | Not specified | Class 8 specifies liquid water content, not PDP (0.5 < C_w ≤ 5 g/m³) | Not specified |
| 9 | Not specified | Class 9 specifies liquid water content, not PDP (5 < C_w ≤ 10 g/m³) | Not specified |
A Note on Class 0: Class 0 is the most stringent but also the most misunderstood. It does not mean zero contamination. It means the air must meet a custom specification, mutually agreed upon by the user and the testing provider, that is stricter than Class 1. It requires specialized testing to verify.
How ISO 8573 Connects to Facility Audits and Compliance
ISO 8573-1 is not enforced on its own; it's the standard referenced by the regulations and quality systems that are enforced. Your facility's specific requirements dictate which ISO 8573-1 purity class you must achieve.
Why this matters for compliance: Failing to meet the compressed air quality specified by your governing standard (like NFPA 99 or an SQF audit) can result in a failed audit, costly production holds, product recalls, or even risks to patient safety. Formal medical gas certification is the only way to prove your systems meet these exacting standards.
SQF and BRC Standards
For the food and beverage industry, both the Safe Quality Food (SQF) Code and the BRC Global Standard for Food Safety mandate that compressed air used in contact with food is clean and does not pose a contamination risk. While they may not explicitly state "Thou shalt meet ISO 8573-1 Class X:Y:Z," they require a risk assessment. The universally accepted method for proving air is not a risk is to test it according to a specific ISO 8573-1 purity class. Often, a class like 2:2:1 or 1:2:1 is chosen for direct or indirect product contact.
NFPA 99 for Medical Air
In hospitals and healthcare facilities in the United States, NFPA 99 (Health Care Facilities Code) is law. For medical air, NFPA 99, Chapter 5, specifies the quality requirements at the source and throughout the distribution system. These requirements are broadly aligned with ISO 8573-1, particularly regarding dew point and oil content. An ASSE 6030 Medical Gas Verifier, like the certified professionals at Medical Testing Solutions, will perform a suite of tests during a medical gas verification to ensure the system meets NFPA 99 standards, which includes verifying the air quality is appropriate for patient use.
Choosing the Right Purity Class for Your Application
Selecting the correct purity class is a balancing act. Over-specifying, for instance, requiring Class 1:1:1 for a general industrial application, leads to unnecessarily high equipment and energy costs. Under-specifying is a serious compliance and safety risk.
This table provides some common starting points:
| Application | Typical Purity Class (P:W:O) | Key Considerations |
|---|---|---|
| Medical Air (NFPA 99) | 2:2:1 or better | Must be free of oil, dry to prevent condensation, and particulate-free. Patient safety is paramount. |
| Food & Beverage (Direct Contact) | 1:2:1 | Extremely low particle and oil content is required to prevent product contamination. |
| Pharmaceutical Manufacturing | 1:2:1 | Stringent control over particulates, moisture, and oil to ensure product purity. |
| Dental Sedation | Varies; see NFPA 99 | Air used for sedation must meet medical-grade standards. Purity is critical when mixing with nitrous oxide. |
| General Shop Air | 4:4:4 | General purpose use; primary concern is protecting pneumatic tools from water and debris. |
Ultimately, the right class depends on a formal risk assessment for your specific process. For complex systems, especially in healthcare, consulting with an expert is the best path forward. The team at Medical Testing Solutions has decades of experience helping facilities determine and achieve the necessary air purity for their applications, from initial medical gas installation to annual testing.
The Process of ISO 8573 Compressed Air Testing
Verifying your air quality is a systematic process that should only be performed by trained and certified professionals using calibrated equipment.
- Step 1: Identify Requirements: The process begins by identifying the specific purity class you need to achieve based on your facility's applications and regulatory bodies.
- Step 2: Select Sampling Points: A certified technician will identify critical points in your compressed air system to take samples, typically at the source and at various points of use.
- Step 3: Capture Samples: Specialized, calibrated equipment is used to capture a precise volume of air. Different tests are required for particles, water (dew point), and oil.
- Step 4: Laboratory Analysis: The samples are sent to an accredited third-party laboratory for analysis. This ensures an unbiased, accurate result.
- Step 5: Interpret the Report: The lab provides a detailed report showing the levels of contaminants. A certified expert can help you interpret these results and confirm whether your system is in compliance.
This is not a DIY task. The accuracy of Medical Testing Solutions's reporting, backed by our ASSE 6000 certified staff, provides the authoritative documentation you need for any audit.
Frequently Asked Questions
Request a quote for your facility
Talk with Medical Testing Solutions about your next inspection, repair or equipment request.