Back to Products

EMSE
EMSE Reciprocating Air Compressor Duplex Plants Systems 3DOX3PT120D
SKU: 3DOX3PT120DMPN: 3DOX3PT120D
Available
Request a quote to confirm current stock & lead time for your facility.
- Horsepower: 3 -Pump SCFM @ 50 PSIG: 12.1 - Tank Size: 120
Quote only — pricing sent within 1 business dayCall (754) 315-1078
This item is quote-only. Submit a request and our team replies with pricing, lead time, and freight within one business day.
1
Before you order, please read our Returns, Cancellation & Refund Policy.
Full manufacturer's warranty included
Product Description
1. RECIPROCATING COMPRESSOR:
A. DUPLEX TANK MOUNTED COMPRESSED AIR PLANTS WITH DESICCANT DRYERS
1. Furnish and install, where shown on the drawings a duplex stack mounted prefabricated medical compressed air plant with desiccant air dryers model 3DOX3PT120D as manufactured by EMSE Corporation, Fairfield, NJ (1-800-935-EMSE)
2. The unit furnished shall be a standard catalog item of the supplier regularly engaged in the business of providing packaged systems for hospitals and laboratories and shall meet and exceed the requirements of NFPA 99.
3. The package shall include two oil-less air compressors and associated equipment, one horizontal ASME tank and one duplex control panel. The entire system including the dryers, filters and monitors shall be mounted on the tank. The only field connections required will be system intake, exhaust and power connection at the control panel. All components shall be completely pre-piped and pre-wired to single-point service connections. All interconnecting piping and wiring shall be completed and operationally tested prior to shipment. Provide liquid tight conduit, fittings and junction boxes for all control and power wiring.
4. The medical air compressors shall be of the totally oil-less reciprocating air-cooled design. Connecting rod and bearings shall be packed with lifetime lubrication and sealed.
5. Each compressor shall be belt driven by a ____ HP, 3 phase, 60 cycle, ______ volt, 1750 RPM, ODP NEMA construction motor. Slide bases for convenient belt tension adjustment and totally enclosed OSHA approved belt guards shall be provided.
6. Each air compressor shall have a capacity of ________ SCFM at 100 PSIG.
7. The system shall include individual compressor inline intake filters, discharge check valves of bronze construction, safety relief valves, bronze intake and discharge flexible connectors, solenoid unloaders, isolation valves, air cooled aftercoolers for each compressor, high discharge temperature shut down switches on each cylinder, pressure control switches, as well as copper tubing with shut-off cock for gauge and switches.
8. The system shall include a 120 gallon pressure storage tank of ASME construction rated for 200 PSI MWP service. The tank shall be equipped with a pressure gauge, safety relief valve, 3 way by-pass, gauge glass and automatic electronic tank drain
with manual override. The inside of the tank shall be coated for rust protection with a two component coating which provides a hard, durable lining.
9. Control System:
a. The system shall include a UL listed control panel in a NEMA 12 enclosure with the following accessories for each pump:
b. Externally operable circuit breaker with door interlock, control circuit transformer with fused primary and secondary coils, H-O-A switch, magnetic starter with 3 leg overload protection, hour meter and motor running light.
c. Provide the panel with a multiple position selector switch for selection of normal operation (automatic alternation) or manual selection of lead and lag pumps if one of the pumps is taken out of service due to scheduled maintenance.
d. Provide audible and visual local alarm (complete with indicating lights and individual sets of auxiliary contacts wired to the terminal strip for remote alarm indication) for the following: compressor temperature malfunction and reserve compressor in use.
e. Provide manual reset for thermal malfunction shut-down. All control and alarm functions shall remain energized while any compressor in the system remains electrically on-line. The lag compressor shall be able to start automatically if the lead compressor fails to operate.
10. Air Treatment:
a. A completely packaged NFPA 99 and NEC compliant assembly featuring dual desiccant air dryers, dual 05 micron pre-filters, dual 0.5 micron after-filters, line pressure regulating valves, dew point monitor, CO monitor and other accessories required to meet and exceed the current code requirements shall be mounted on the compressor system base. All components shall be completely pre-piped and pre-wired to single-point service connections.
b. There shall be two identical banks of air treatment equipment, piped in parallel and provided with valves to by-pass either filter set for element replacement, maintenance and repair work on one of the sets while still treating medical compressed air through the other set without any sacrifice in air quality. Each bank consists of three stages of treatment.
Specifications
- MPN
- 3DOX3PT120D
Need a Quote for This Product?
We offer competitive pricing on all medical gas equipment. Get a fast, no-obligation quote from our team — most quotes returned within 1 business day.
1-Day Response ASSE Certified Free Quote
~2.4 hr avg reply today17 handled today· 24-hr guarantee
Get a custom quote — same-day in most cases
Our ASSE-certified team can bundle this item with installation, verification, and freight to lock in one line-item price. No back-and-forth.
- NFPA 99 compliant
- Nationwide freight
- Install + verify add-on
Why Facilities Trust Us
ASSE 6010 · 6020 · 6030 · 6040 Certified
Bonded & Insured · Multi-Million Dollar Coverage
SAM / DUNS Registered
Thousands of Facilities Served Nationwide
Trusted by NASA, DoD, VA, Tesla & More
Manufacturer's Warranty Included