Compressed Air & Breathing Air Testing
ISO 8573, NFPA 1989, OSHA Grade D, dive, food, pharma, and pure gas testing — delivered through an ISO/IEC 17025:2017 accredited laboratory. Sampling kits ship to all 50 states; your on-site team collects the sample in minutes.
Why Compressed Air Testing Matters
Over 70% of production facilities rely on compressed air somewhere in the process. When compressed air contacts your product — directly or indirectly — it becomes a regulated hazard. Contaminated breathing air can injure or kill firefighters and divers, and a single failed audit can shut down a food, pharma, or medical-device line.
What We Test
From SCBA fill stations to GMP cleanrooms, our accredited lab partner covers every major compressed air and pure gas specification.
ISO 8573 Compressed Air Testing
Full ISO 8573-1 testing for particles, water, total oil (aerosol + vapor), and microorganisms. Meet SQF, BRC, Primus, ISPE, and customer audit requirements.
NFPA 1989 Breathing Air (Fire)
SCBA fill-station breathing air testing to NFPA 1989. Quarterly testing kits ship with prepaid return — accredited lab report in days.
Sport & Commercial Dive Air
Compressed breathing air analysis for dive shops, commercial divers, and PADI members — CO, CO₂, oxygen, moisture, oil, and odor.
OSHA Grade D Industrial Breathing Air
Meet OSHA 29 CFR 1910.134 Grade D requirements for sandblasting, painting, welding, and confined-space respirator use.
Pharma, Med Device & Cleanroom Air
Process gas and compressed air testing aligned with ISPE, ISO 8573, ISO 14644, and USP requirements for GMP environments.
Food & Beverage Compressed Air
Food-contact and indirect-contact compressed air testing to support SQF, BRC, FSSC 22000, and Primus food-safety audits.
Environmental & Microbial Monitoring
Contact plates, surface swabs, and ambient air sampling for cleanroom and controlled-environment microbial monitoring.
Pure Gas & Instrument Air Testing
Nitrogen, argon, helium, CO₂, and instrument air testing to ANSI/ISA S7.0.01 and customer-specific pure-gas specifications.
Industries We Serve
Fire Departments & SCBA Fill Stations
NFPA 1989 quarterly breathing air testing for municipal fire, industrial fire brigades, and rescue dive teams.
Dive Shops & Commercial Divers
PADI-recognized dive air testing for sport diving operators, commercial dive contractors, and marine vessels.
Manufacturing & Industrial
ISO 8573 compressed air testing for automotive, aerospace, electronics, and general manufacturing facilities.
Food & Beverage Processors
Compressed air testing for bottling, packaging, dairy, bakery, and FDA-regulated food-contact applications.
Pharmaceutical & Medical Device
GMP-compliant testing for compounding, sterile fill, API manufacturing, and medical device clean assembly.
Laboratories & Cleanrooms
Environmental monitoring and pure gas testing for research labs, ISO 14644 cleanrooms, and controlled environments.
How Nationwide Testing Works
Tell us your spec
Choose the standard (ISO 8573, NFPA 1989, OSHA, ISPE, dive, etc.) and the number of sampling points.
Kit ships to your site
We ship a pre-assembled sampling kit with instructions, sampling media, and a prepaid return label.
Your team samples
An on-site employee connects to your sample port for a few minutes per location — no pumps, no calibration.
Audit-ready report
Accredited lab analyzes the sample and issues a pass/fail PDF report in 5–10 business days.
ISO 8573-1:2010 Purity Classes
ISO 8573-1 is the international standard that defines the major contaminants in compressed air — particles, water vapor and total oil — and assigns each a numbered purity class. Use it as the common language between your facility, your auditors and our accredited lab.
| Class | Particles (max per m³) | Dewpoint (°C) | Dewpoint (°F) | Total Oil |
|---|---|---|---|---|
| 0 | More stringent than Class 1 — user/supplier specified | User specified | User specified | < Class 1 |
| 1 | ≤20,000 (0.1–0.5 µm), ≤400 (0.5–1 µm), ≤10 (1–5 µm) | ≤ −70 °C | ≤ −94 °F | ≤ 0.01 mg/m³ |
| 2 | ≤400,000 / ≤6,000 / ≤100 | ≤ −40 °C | ≤ −40 °F | ≤ 0.1 mg/m³ |
| 3 | — / ≤90,000 / ≤1,000 | ≤ −20 °C | ≤ −4 °F | ≤ 1 mg/m³ |
| 4 | — / — / ≤10,000 | ≤ +3 °C | ≤ +37 °F | ≤ 5 mg/m³ |
| 5 | — / — / ≤100,000 | ≤ +7 °C | ≤ +45 °F | — |
| 6 | ≤5 mg/m³ (>5 µm) | ≤ +10 °C | ≤ +50 °F | — |
Class 0 is more stringent than Class 1 and is defined by the user or equipment supplier. Total Oil per ISO 8573 includes aerosol + vapor; liquid oil is sampled separately when wall flow is present. Particle Class 1 (0.1–0.5 µm range) requires a laser particle counter — rental available.
Test Packages
Pick the package that matches your audit. PWO covers Particles, Water and Oil. Micro covers bacteria, yeast and mold per ISO 8573-7.
PWO Packages (Particles · Water · Oil)
PWO Basic
Entry level- Particles, Water, Oil to ISO 8573
- Meets ISPE & ANSI baseline
- Audit-ready PDF report
- 5–10 business-day turnaround
PWO Standard
Most popular- All Basic parameters
- Higher purity class targets
- Meets SQF, BRC & Primus
- Total Oil (aerosol + vapor)
PWO Pro
High-risk / GMP- Class 1–2 particle resolution (laser counter)
- Microscopic particle ID
- Total Oil + dewpoint precision
- Meets BCAS & high-risk SQF/BRC
Micro Packages (ISO 8573-7)
Micro Basic
- Total Plate Count (TPC)
- Yeast & Mold enumeration
- ISO 8573-7 microbial monitoring
- Pinocchio Super 1 sampler
Micro Pro
- TPC + Yeast & Mold
- Gram staining for all colonies
- Organism ID add-on (Genus & Species via Biolog)
- Meets HACCP & BCAS risk programs
Every kit ships pre-assembled with sampling media, AirCheck™ K810 hardware (or Pinocchio Super 1 for micro), an adapter, instructions, a data sheet, and a prepaid Priority Mail Express return label. No pumps, calibration, or specialized training required at the site.
Sources of Contamination
If a sample fails, use this troubleshooting matrix to narrow down the likely root cause before re-testing. Our team will help you investigate and document corrective action.
Particles
- Improper filter maintenance or damaged elements
- Insufficient purge after piping changes
- Rust, scale and metal shavings in distribution
- Compressor air-intake contamination
- Poorly located or new sampling port
Water
- Polymer/rubber hose moisture absorption
- Failed or undersized desiccant/refrigerated dryer
- Condensate traps and dead-end drops
- Long distribution runs with temperature drop
- Valves and filter malfunctions
Oil (Total)
- Worn or unmaintained coalescing filters
- Lubricated compressor carryover
- Even oil-free compressors: atmospheric vapor + cleaning solvents
- Improperly sized point-of-use filtration
- Filters not designed for application
Microorganisms
- Standing water in piping or filter bowls
- Biofilm in rubber tubing & gaskets
- Oil + water combination feeding growth
- Lack of routine sanitization at points of use
- Intake air drawn from contaminated environments
Build Your Monitoring Plan
A defensible monitoring program answers three questions. Our experts can help you build the plan, document it for auditors, and set up calendar reminders.
What contaminants do I test?
Drive testing from your audit. SQF and BRC require Particles, Water, Oil and microorganisms. NFPA 1989 fire-service air requires CO, CO₂, O₂, moisture, oil mist and odor. OSHA Grade D requires CO, CO₂, O₂, oil and odor. ISPE GMP environments add ISO 8573-7 microbial monitoring.
Where do I sample?
Sample at the point of use — as close to the product or end user as practical. Test every critical production line, every SCBA fill station, and at minimum one downstream-of-filtration point per air receiver. Document each port with a unique ID and re-use it every cycle.
How often should I retest?
NFPA 1989: every 3 months. OSHA Grade D and most food/pharma quality systems: at least annually, quarterly for high-risk. ISO 8573 for SQF/BRC: at least annually plus after any system change, filter replacement, or compressor service. After a fail: re-test immediately after corrective action, then resume normal cadence.
Why Choose MTS for Compressed Air Testing
- ISO/IEC 17025:2017 accredited laboratory partner (A2LA)
- Nationwide — kits ship anywhere in the U.S., self-collected on-site
- All-inclusive kit pricing — sampling media, lab analysis, and report
- Fast turnaround — most reports delivered in 5–10 business days
- ISO 8573, NFPA 1989, NFPA 99, OSHA, CGA, CSA, ISPE & USP methods
- Particles, water (dewpoint), oil (aerosol + vapor), and microorganisms
- Pre-paid return shipping included with every kit
- Audit-ready PDF reports with method, limits, and pass/fail summary
- 30+ years of compressed-air testing expertise from our lab partner
- Expert consultation on sampling points, frequency, and corrective action
Testing is performed by our ISO/IEC 17025:2017 accredited laboratory partner with over 30 years of compressed air testing experience. All reports are accredited and audit-ready.
90% faster than our 24-hour service commitment.
Order a Compressed Air Testing Kit
Tell us your standard, industry, and number of sampling points. We'll respond within 1 business day with a quote and shipping timeline.
Not Sure Which Test You Need?
Tell us your industry and which audit or standard you're preparing for — we'll recommend the right kit, parameters, and sampling frequency.
Craftsmanship Warranty Included
Every service is backed by our craftsmanship warranty — we stand behind our work.
Sizing a medical air plant?
Enter your room counts and get a peak SCFM demand plus a recommended duplex, triplex, or quadruplex configuration sized to NFPA 99 redundancy — free, no login.
Frequently Asked Questions
Explore Our Other Services
Medical Testing Solutions provides a complete range of medical gas services nationwide.
Medical Gas Verification
ASSE 6030 verification for new installs & renovations
Annual Inspections
ASSE 6040 annual compliance inspections
Medical Gas Installation
ASSE 6010 certified pipeline installation
Medical Gas Maintenance
Preventative maintenance & emergency repairs
Medical Gas Training
ASSE 6010–6040 certification courses
Line Isolation Monitor Testing
NFPA 99 LIM testing & calibration
Dental Flowmeter Repair
$950 flat-rate repair & NIST calibration
USP 797 & 800 Certification
Cleanroom PEC certification & viable sampling
WAG & Chemical Vapor Monitoring
AIHA-accredited monitoring badges & lab analysis
Chemical Exposure Monitoring
N₂O, formaldehyde, glutaraldehyde/OPA & O₂ deficiency testing
Industries We Serve
Hospitals, ASCs, dental, veterinary, dermatology & more
All Medical Gas Services
Complete service overview & hub page
Ready to Test Your Compressed Air?
Order a kit, get audit-ready results, and protect your team and product. Nationwide service through our ISO 17025 accredited laboratory partner.
ASSE 6010 · 6020 · 6030 · 6040 Certified | Bonded & Insured | SAM/DUNS Registered